ARC-19509
ArcVision Technology Corp.
3
3. Installation
Back Panel
3.1 Power Supply
DC 12V ±10%, 830mA, DC 12V/1A switching mode power adapter is recommended.
3.2 ALARM I/O
There is a DB15 connector on the left side of the back panel, which is connected to the external alarm sensor and time lapse VCR
trigger input.
1
GND Ground
2 ALARM IN-1 External alarm input 1
3 ALARM IN-2 External alarm input 2
4 ALARM IN-3 External alarm input 3
5 ALARM IN-4 External alarm input 4
6 ALARM IN-5 External alarm input 5
7 ALARM IN-6 External alarm input 6
8 ALARM IN-7 External alarm input 7
9 GND Ground
10
REC TRIG External recoder trigger input
11 RELAY OUT-COM Relay output COM terminal
12 RELAY OUT-N.C. Relay output normal close terminal
13 RELAY OUT-N.O. Relay output normal open terminal
14 ALARM IN-9 External alarm input 9
15 ALARM IN-8 External alarm input 8
3.3 REC TRIGGER INPUT PORT
REC trigger input port is on the right side of the DB15. It is for VCR/DVR trigger signal input.
3.4 VIDEO OUT
3.4.1 MONITOR OUT
Connect the BNC connector for “MONITOR OUT” on the Mutiplexer and the other part to “VIDEO IN” on the Monitor.
3.4.2 CALL OUT
Connect the BNC connector for “CALL OUT” on the Mutiplexer and the other part to “VIDEO IN” on another Monitor.
3.4.3 REC OUT
Connect BNC connector for “REC OUT” on the Multiplexer and the other part to “VCR IN” on the VCR.
3.5 REC IN
Connect the BNC connector for “REC IN” to the VCR for “VIDEO OUT” on the VCR.
3.6 VIDEO IN & LOOP OUT
The camera line is connected to Camera-Video IN and the nine-channel loop-out path is supplied for alternative usage.