5. Operation Mode
There are four operational modes on the multiplexer.
Mode Description
Normal The multiplexer automatically enters into normal mode, when the power has been put on.
Press camera selection key to view the full-image.
Press
<MULTI-WIN> key to view multi-window images. Multi-window supports 4,6 and 9 image split.
This mode supports freeze function under multi-window and full-image.
Multi-windows freeze:
1.
Under multi-window of the normal mode, presses <FREEZE> key to enter freeze function.
User can freeze or release an
channel selected
while the LED indicator of the Freeze ke
is
“ON”.
2.
Press camera channel selection key to select a camera channel that you want to freeze.
the image of the related camera is than frozen.
In order to release frozen ima
e
s
ress the camera selection ke
a
ain to select a camera
when the LED indicator for the camera channel selection lights up, it indicates that the ima
e
has been released.
When the light of the LED indicator for the camera goes off the image is released and be
ins
to refresh.
3.
User can freeze and release image(s) for every camera channel independently.
4.
To quit the freeze mode, press <FREEZE> key again to return to multi-window of normal mode.
Full-image freeze:
1.
Under full-view of the selected camera channel
ress camera channel selection ke
a
ain to
freeze the image. The LED indicator of selected channel begins to flash.
2.
Press <MULTI-WIN> key or camera channel selection keys to release the camera channel to
multi-window image or full-image of the selected camera channel.
This mode supports 2X zoom function under full-image.
1.
Under full-image press <ZOOM> key, the zoom LED indicator lights up and 2X ima
e dis
la
s
on monitor.
2.
Use the blue arrow key to pan or tilt the 2X image.
3.
Press <ZOOM> again to leave zoom function to normal full-image.
Auto
Sequence
Under normal mode, press <SEQ> key to enter sequence mode.
Under this mode, the monitor displays images according to user’s definition of channel sequences and
dwell time.
Refer to page 10, “8.2 AUTO CHANNEL SEQUENCE” for more details.
To exit sequence mode:
1.
Press camera channel selection key or <MULTI-WIN> key to exit auto se
uence mode and enter
normal mode.
2.
Press <PLAYBACK> key to enter playback mode.
3.
Press <MENU> key to enter menu set up mode.
Playback In normal or sequence mode, press <PLAYBACK> key to enter the playback mode.
Under this mode user can playback VCR that was recorded by this multiplexer.
It is impossible to view images recorded by another multiplexer.
Support multi-windows images and full-image view.
Multi-window format is deferent from normal mode. It only supports 4 and 9 split.
Support freeze function for multi-win image and full-image. It is the same as normal mode.
Support 2X zoom function under full-image. It is the same as normal mode.
Press
<PLAYBACK> key again to exit playback mode and goes back to normal mode.
Menu set up Under normal or sequence mode, press <MENU> key to enter menu set up mode.
Refer page 8, “8. Menu set up” for more details.